Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 203
Filtrar
1.
J Environ Manage ; 358: 120832, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38599089

RESUMO

Polyethylene (PE) is the most productive plastic product and includes three major polymers including high-density polyethylene (HDPE), linear low-density polyethylene (LLDPE) and low-density polyethylene (LDPE) variation in the PE depends on the branching of the polymer chain and its crystallinity. Tenebrio obscurus and Tenebrio molitor larvae biodegrade PE. We subsequently tested larval physiology, gut microbiome, oxidative stress, and PE degradation capability and degradation products under high-purity HDPE, LLDPE, and LDPE powders (<300 µm) diets for 21 days at 65 ± 5% humidity and 25 ± 0.5 °C. Our results demonstrated the specific PE consumption rates by T. molitor was 8.04-8.73 mg PE ∙ 100 larvae-1⋅day-1 and by T. obscurus was 7.68-9.31 for LDPE, LLDPE and HDPE, respectively. The larvae digested nearly 40% of the ingested three PE and showed similar survival rates and weight changes but their fat content decreased by 30-50% over 21-day period. All the PE-fed groups exhibited adverse effects, such as increased benzoquinone concentrations, intestinal tissue damage and elevated oxidative stress indicators, compared with bran-fed control. In the current study, the digestive tract or gut microbiome exhibited a high level of adaptability to PE exposure, altering the width of the gut microbial ecological niche and community diversity, revealing notable correlations between Tenebrio species and the physical and chemical properties (PCPs) of PE-MPs, with the gut microbiome and molecular weight change due to biodegradation. An ecotoxicological simulation by T.E.S.T. confirmed that PE degradation products were little ecotoxic to Daphnia magna and Rattus norvegicus providing important novel insights for future investigations into the environmentally-friendly approach of insect-mediated biodegradation of persistent plastics.

2.
Talanta ; 274: 125997, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569369

RESUMO

Cyanidin-3-O-glucoside (C3G), a natural antioxidant, plays multiple physiological or pathological roles in maintaining human health; thereby, designing advanced sensors to achieve specific recognition and high-sensitivity detection of C3G is significant. Herein, an imprinted-type electrochemiluminescence (ECL) sensing platform was developed using core-shell Ru@SiO2-CMIPs, which were prepared by covalent organic framework (COF)-based molecularly imprinted polymers (CMIPs) embedded in luminescent Ru@SiO2 cores. The C3G-imprinted COF shell not only helps generate a steady-enhanced ECL signal, but also enables specific recognition of C3G. When C3G is bound to Ru@SiO2-CMIPs with abundant imprinted cavities, resonance energy transfer (RET) behavior is triggered, resulting in a quenched ECL response. The constructed Ru@SiO2-CMIPs nanoprobes exhibit ultra-high sensitivity, absolute specificity, and an ultra-low detection limit (0.15 pg mL-1) for analyzing C3G in food matrices. This study provides a means to construct an efficient and reliable molecular imprinting-based ECL sensor for food analysis.

3.
Curr Med Imaging ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38639284

RESUMO

BACKGROUND AND OBJECTIVE: The incidence of stroke is rising, and it is the second major cause of mortality and the third leading cause of disability around the globe. The goal of this study was to rapidly and accurately identify carotid plaques and automatically quantify plaque burden using our automated tracking and segmentation US-video system. METHODS: We collected 88 common carotid artery transection videos (11048 frames) with a history of atherosclerosis or risk factors for atherosclerosis, which were randomly divided into training, test, and validation sets using a 6:3:1 ratio. We first trained different segmentation models to segment the carotid intima and adventitia, and calculate the maximum plaque burden automatically. Finally, we statistically analyzed the plaque burden calculated automatically by the best model and the results of manual labeling by senior sonographers. RESULTS: Of the three Artificial Intelligence (AI) models, the Robust Video Matting (RVM) segmentation model's carotid intima and adventitia Dice Coefficients (DC) were the highest, reaching 0.93 and 0.95, respectively. Moreover, the RVM model has shown the strongest correlation coefficient (0.61±0.28) with senior sonographers, and the diagnostic effectiveness between the RVM model and experts was comparable with paired-t test and Bland-Altman analysis [P= 0.632 and ICC 0.01 (95% CI: -0.24~0.27), respectively]. CONCLUSION: Our findings have indicated that the RVM model can be used in ultrasound carotid video. The RVM model can automatically segment and quantify atherosclerotic plaque burden at the same diagnostic level as senior sonographers. The application of AI to carotid videos offers more precise and effective methods to evaluate carotid atherosclerosis in clinical practice.

4.
Water Res ; 256: 121600, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38640563

RESUMO

A limited understanding of microbial interactions and community assembly mechanisms in constructed wetlands (CWs), particularly with different substrates, has hampered the establishment of ecological connections between micro-level interactions and macro-level wetland performance. In this study, CWs with distinct substrates (zeolite, CW_A; manganese ore, CW_B) were constructed to investigate the nutrient removal efficiency, microbial interactions, metabolic mechanisms, and ecological assembly for treating rural sewage with a low carbon-to-nitrogen ratio. CW_B showed higher removal of ammonia nitrogen and total nitrogen by about 1.75-6.75 % and 3.42-5.18 %, respectively, compared to CW_A. Candidatus_Competibacter (denitrifying glycogen-accumulating bacteria) was the dominant microbial genus in CW_A, whereas unclassified_f_Blastocatellaceae (involved in carbon and nitrogen transformation) dominated in CW_B. The null model revealed that stochastic processes (drift) dominated community assembly in both CWs; however, deterministic selection accounted for a higher proportion in CW_B. Compared to those in CW_A, the interactions between microbes in CW_B were more complex, with more key microbes involved in carbon, nitrogen, and phosphorus conversion; the synergistic cooperation of functional bacteria facilitated simultaneous nitrification-denitrification. Manganese ores favour biofilm formation, increase the activity of the electron transport system, and enhance ammonia oxidation and nitrate reduction. These results elucidated the ecological patterns exhibited by microbes under different substrate conditions thereby contributing to our understanding of how substrates shape distinct microcosms in CW systems. This study provides valuable insights for guiding the future construction and management of CWs.

5.
Vascular ; : 17085381241246312, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656244

RESUMO

OBJECTIVES: Assessment of plaque stenosis severity allows better management of carotid source of stroke. Our objective is to create a deep learning (DL) model to segment carotid intima-media thickness and plaque and further automatically calculate plaque stenosis severity on common carotid artery (CCA) transverse section ultrasound images. METHODS: Three hundred and ninety images from 376 individuals were used to train (235/390, 60%), validate (39/390, 10%), and test (116/390, 30%) on a newly proposed CANet model. We also evaluated the model on an external test set of 115 individuals with 122 images acquired from another hospital. Comparative studies were conducted between our CANet model with four state-of-the-art DL models and two experienced sonographers to re-evaluate the present model's performance. RESULTS: On the internal test set, our CANet model outperformed the four comparative models with Dice values of 95.22% versus 90.15%, 87.48%, 90.22%, and 91.56% on lumen-intima (LI) borders and 96.27% versus 91.40%, 88.94%, 91.19%, and 92.88% on media-adventitia (MA) borders. On the external test set, our model still produced excellent results with a Dice value of 92.41%. Good consistency of stenosis severity calculation was observed between CANet model and experienced sonographers, with Intraclass Correlation Coefficient (ICC) of 0.927 and 0.702, Pearson's Correlation Coefficient of 0.928 and 0.704 on internal and external test set, respectively. CONCLUSIONS: Our CANet model achieved excellent performance in the segmentation of carotid IMT and plaques as well as automated calculation of stenosis severity.

6.
iScience ; 27(4): 109403, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38523785

RESUMO

We evaluated the diagnostic performance of a multimodal deep-learning (DL) model for ovarian mass differential diagnosis. This single-center retrospective study included 1,054 ultrasound (US)-detected ovarian tumors (699 benign and 355 malignant). Patients were randomly divided into training (n = 675), validation (n = 169), and testing (n = 210) sets. The model was developed using ResNet-50. Three DL-based models were proposed for benign-malignant classification of these lesions: single-modality model that only utilized US images; dual-modality model that used US images and menopausal status as inputs; and multi-modality model that integrated US images, menopausal status, and serum indicators. After 5-fold cross-validation, 210 lesions were tested. We evaluated the three models using the area under the curve (AUC), accuracy, sensitivity, and specificity. The multimodal model outperformed the single- and dual-modality models with 93.80% accuracy and 0.983 AUC. The Multimodal ResNet-50 DL model outperformed the single- and dual-modality models in identifying benign and malignant ovarian tumors.

7.
Ultrasound Med Biol ; 50(5): 722-728, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38369431

RESUMO

OBJECTIVE: Although ultrasound is a common tool for breast cancer screening, its accuracy is often operator-dependent. In this study, we proposed a new automated deep-learning framework that extracts video-based ultrasound data for breast cancer screening. METHODS: Our framework incorporates DenseNet121, MobileNet, and Xception as backbones for both video- and image-based models. We used data from 3907 patients to train and evaluate the models, which were tested using video- and image-based methods, as well as reader studies with human experts. RESULTS: This study evaluated 3907 female patients aged 22 to 86 years. The results indicated that the MobileNet video model achieved an AUROC of 0.961 in prospective data testing, surpassing the DenseNet121 video model. In real-world data testing, it demonstrated an accuracy of 92.59%, outperforming both the DenseNet121 and Xception video models, and exceeding the 76.00% to 85.60% accuracy range of human experts. Additionally, the MobileNet video model exceeded the performance of image models and other video models across all evaluation metrics, including accuracy, sensitivity, specificity, F1 score, and AUC. Its exceptional performance, particularly suitable for resource-limited clinical settings, demonstrates its potential for clinical application in breast cancer screening. CONCLUSIONS: The level of expertise reached by the video models was greater than that achieved by image-based models. We have developed an artificial intelligence framework based on videos that may be able to aid breast cancer diagnosis and alleviate the shortage of experienced experts.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Inteligência Artificial , Estudos Prospectivos , Ultrassonografia
8.
Comput Methods Programs Biomed ; 245: 108039, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38266556

RESUMO

BACKGROUND: The risk of ductal carcinoma in situ (DCIS) identified by biopsy often increases during surgery. Therefore, confirming the DCIS grade preoperatively is necessary for clinical decision-making. PURPOSE: To train a three-classification deep learning (DL) model based on ultrasound (US), combining clinical data, mammography (MG), US, and core needle biopsy (CNB) pathology to predict low-grade DCIS, intermediate-to-high-grade DCIS, and upstaged DCIS. MATERIALS AND METHODS: Data of 733 patients with 754 DCIS cases confirmed by biopsy were retrospectively collected from May 2013 to June 2022 (N1), and other data (N2) were confirmed by biopsy as low-grade DCIS. The lesions were randomly divided into training (n=471), validation (n=142), and test (n = 141) sets to establish the DCIS-Net. Information on the DCIS-Net, clinical (age and sign), US (size, calcifications, type, breast imaging reporting and data system [BI-RADS]), MG (microcalcifications, BI-RADS), and CNB pathology (nuclear grade, architectural features, and immunohistochemistry) were collected. Logistic regression and random forest analyses were conducted to develop Multimodal DCIS-Net to calculate the specificity, sensitivity, accuracy, receiver operating characteristic curve, and area under the curve (AUC). RESULTS: In the test set of N1, the accuracy and AUC of the multimodal DCIS-Net were 0.752-0.766 and 0.859-0.907 in the three-classification task, respectively. The accuracy and AUC for discriminating DCIS from upstaged DCIS were 0.751-0.780 and 0.829-0.861, respectively. In the test set of N2, the accuracy and AUC of discriminating low-grade DCIS from upstaged low-grade DCIS were 0.769-0.987 and 0.818-0.939, respectively. DL was ranked from one to five in the importance of features in the multimodal-DCIS-Net. CONCLUSION: By developing the DCIS-Net and integrating it with multimodal information, diagnosing low-grade DCIS, intermediate-to high-grade DCIS, and upstaged DCIS is possible. It can also be used to distinguish DCIS from upstaged DCIS and low-grade DCIS from upstaged low-grade DCIS, which could pave the way for the DCIS clinical workflow.


Assuntos
Neoplasias da Mama , Calcinose , Carcinoma Ductal de Mama , Carcinoma Intraductal não Infiltrante , Patologia Cirúrgica , Humanos , Feminino , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/cirurgia , Estudos Retrospectivos , Mamografia , Neoplasias da Mama/diagnóstico por imagem
9.
Comput Biol Med ; 169: 107958, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38194778

RESUMO

BACKGROUND: Over the past few decades, agonists binding to the benzodiazepine site of the GABAA receptor have been successfully developed as clinical drugs. Different modulators (agonist, antagonist, and reverse agonist) bound to benzodiazepine sites exhibit different or even opposite pharmacological effects, however, their structures are so similar that it is difficult to distinguish them based solely on molecular skeleton. This study aims to develop classification models for predicting the agonists. METHODS: 306 agonists or non-agonists were collected from literature. Six machine learning algorithms including RF, XGBoost, AdaBoost, GBoost, SVM, and ANN algorithms were employed for model development. Using six descriptors including 1D/2D Descriptors, ECFP4, 2D-Pharmacophore, MACCS, PubChem, and Estate fingerprint to characterize chemical structures. The model interpretability was explored by SHAP method. RESULTS: The best model demonstrated an AUC value of 0.905 and an MCC value of 0.808 for the test set. The PubMac-based model (PubMac-GB) achieved best AUC values of 0.935 for test set. The SHAP analysis results emphasized that MaccsFP62, ECFP_624, ECFP_724, and PubchemFP213 were the crucial molecular features. Applicability domain analysis was also performed to determine reliable prediction boundaries for the model. The PubMac-GB model was applied to virtual screening for potential GABAA agonists and the top 100 compounds were given. CONCLUSION: Overall, our ensemble learning-based model (PubMac-GB) achieved comparable performance and would be helpful in effectively identifying agonists of GABAA receptors.


Assuntos
Agonistas de Receptores de GABA-A , Receptores de GABA-A , Receptores de GABA-A/metabolismo , Benzodiazepinas , Aprendizado de Máquina , Ácido gama-Aminobutírico
10.
Diabetol Metab Syndr ; 16(1): 7, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172956

RESUMO

PURPOSE: Prolonged exposure to plasma free fatty acids (FFAs) leads to impaired glucose tolerance (IGT) which can progress to type 2 diabetes (T2D) in the absence of timely and effective interventions. High-fat diet (HFD) leads to chronic inflammation and oxidative stress, impairing pancreatic beta cell (PBC) function. While Didymin, a flavonoid glycoside derived from citrus fruits, has beneficial effects on inflammation dysfunction, its specific role in HFD-induced IGT remains yet to be elucidated. Hence, this study aims to investigate the protective effects of Didymin on PBCs. METHODS: HFD-induced IGT mice and INS-1 cells were used to explore the effect and mechanism of Didymin in alleviating IGT. Serum glucose and insulin levels were measured during the glucose tolerance and insulin tolerance tests to evaluate PBC function and insulin resistance. Next, RNA-seq analysis was performed to identify the pathways potentially influenced by Didymin in PBCs. Furthermore, we validated the effects of Didymin both in vitro and in vivo. Mitochondrial electron transport inhibitor (Rotenone) was used to further confirm that Didymin exerts its ameliorative effect by enhancing mitochondria function. RESULTS: Didymin reduces postprandial glycemia and enhances 30-minute postprandial insulin levels in IGT mice. Moreover, Didymin was found to enhance mitochondria biogenesis and function, regulate insulin secretion, and alleviate inflammation and apoptosis. However, these effects were abrogated with the treatment of Rotenone, indicating that Didymin exerts its ameliorative effect by enhancing mitochondria function. CONCLUSIONS: Didymin exhibits therapeutic potential in the treatment of HFD-induced IGT. This beneficial effect is attributed to the amelioration of PBC dysfunction through improved mitochondrial function.

11.
BMC Med Inform Decis Mak ; 24(1): 1, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166852

RESUMO

BACKGROUND: The application of artificial intelligence (AI) in the ultrasound (US) diagnosis of breast cancer (BCa) is increasingly prevalent. However, the impact of US-probe frequencies on the diagnostic efficacy of AI models has not been clearly established. OBJECTIVES: To explore the impact of using US-video of variable frequencies on the diagnostic efficacy of AI in breast US screening. METHODS: This study utilized different frequency US-probes (L14: frequency range: 3.0-14.0 MHz, central frequency 9 MHz, L9: frequency range: 2.5-9.0 MHz, central frequency 6.5 MHz and L13: frequency range: 3.6-13.5 MHz, central frequency 8 MHz, L7: frequency range: 3-7 MHz, central frequency 4.0 MHz, linear arrays) to collect breast-video and applied an entropy-based deep learning approach for evaluation. We analyzed the average two-dimensional image entropy (2-DIE) of these videos and the performance of AI models in processing videos from these different frequencies to assess how probe frequency affects AI diagnostic performance. RESULTS: The study found that in testing set 1, L9 was higher than L14 in average 2-DIE; in testing set 2, L13 was higher in average 2-DIE than L7. The diagnostic efficacy of US-data, utilized in AI model analysis, varied across different frequencies (AUC: L9 > L14: 0.849 vs. 0.784; L13 > L7: 0.920 vs. 0.887). CONCLUSION: This study indicate that US-data acquired using probes with varying frequencies exhibit diverse average 2-DIE values, and datasets characterized by higher average 2-DIE demonstrate enhanced diagnostic outcomes in AI-driven BCa diagnosis. Unlike other studies, our research emphasizes the importance of US-probe frequency selection on AI model diagnostic performance, rather than focusing solely on the AI algorithms themselves. These insights offer a new perspective for early BCa screening and diagnosis and are of significant for future choices of US equipment and optimization of AI algorithms.


The research on artificial intelligence-assisted breast diagnosis often relies on static images or dynamic videos obtained from ultrasound probes with different frequencies. However, the effect of frequency-induced image variations on the diagnostic performance of artificial intelligence models remains unclear. In this study, we aimed to explore the impact of using ultrasound images with variable frequencies on AI's diagnostic efficacy in breast ultrasound screening. Our approach involved employing a video and entropy-based feature breast network to compare the diagnostic efficiency and average two-dimensional image entropy of the L14 (frequency range: 3.0-14.0 MHz, central frequency 9 MHz), L9 (frequency range: 2.5-9.0 MHz, central frequency 6.5 MHz) linear array probe and L13 (frequency range: 3.6-13.5 MHz, central frequency 8 MHz), and L7 (frequency range: 3-7 MHz, central frequency 4.0 MHz) linear array probes. The results revealed that the diagnostic efficiency of AI models differed based on the frequency of the ultrasound probe. It is noteworthy that ultrasound images acquired with different frequency probes exhibit different average two-dimensional image entropy, while higher average two-dimensional image entropy positively affect the diagnostic performance of the AI model. We concluded that a dataset with higher average two-dimensional image entropy is associated with superior diagnostic efficacy for AI-based breast diagnosis. These findings contribute to a better understanding of how ultrasound image variations impact AI-assisted breast diagnosis, potentially leading to improved breast cancer screening outcomes.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Humanos , Feminino , Entropia , Ultrassonografia , Neoplasias da Mama/diagnóstico por imagem , Algoritmos
12.
Spectrochim Acta A Mol Biomol Spectrosc ; 309: 123840, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38217985

RESUMO

Iron and amino acids are essential nutrients for living organisms, and their deficiency or excess can cause a range of diseases. Therefore, there is considerable interest in developing sensing assays capable of detecting these nutrients with sensitivity, selectivity, and multifunctionality even in complex environments. In this report, hydrothermally synthesized blue fluorescent carbon dots (C-dots) from zinc gluconate were utilized for the detection of Fe3+ and lysine via "on-off" and "on-off-on" mechanisms, respectively. Specifically, the Fe3+ sensing assay achieved a broad linear range of 0-200 µM and a low limit of detection (LOD) of 1.9 µM. It is worth mentioning that the assay was also well adapted to natural aqueous environments (e.g., lake water), and its linear detection range could be extended to 0-1000 µM with a LOD of 3.3 µM. Furthermore, the assay was also effective for intracellular Fe3+ tracking. Most importantly, the assay could also be applied for the quantitative detection of lysine with a linear range of 0-1200 µM and LOD of 8.6 µM. Systematic mechanistic studies revealed that Fe3+ sensing was based on a static quenching process between C-dots and Fe3+, whereas a stronger complexation might have formed between Fe3+ and Lys, leading to the release of C-dots and thus the recovery of fluorescence.


Assuntos
Corantes Fluorescentes , Pontos Quânticos , Corantes Fluorescentes/química , Pontos Quânticos/química , Lisina , Carbono/química , Água , Espectrometria de Fluorescência
13.
Chem Commun (Camb) ; 60(11): 1492-1495, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38224160

RESUMO

A base-promoted olefin skeletal rearrangement strategy from para-quinone methides (p-QMs) and N-fluoroarenesulfonamides is reported, enabling direct nitrogen insertion of olefins to produce a series of multiarylated (Z)-N-sulfonyl amidines with complete stereoselectivity and generally good yields. Using p-QMs without o-hydroxy substituents gave triarylated N-sulfonyl amidines, whereas tetraarylated N,N'-disulfonyl amidines were synthesized with the existence of o-hydroxy groups.

14.
Acad Radiol ; 31(1): 221-232, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37330355

RESUMO

RATIONALE AND OBJECTIVES: It is still challenging for cardiac magnetic resonance (CMR) to detect ischemic heart disease (IHD) without the use of gadolinium contrast. We aimed to evaluate the potential value of adenosine triphosphate (ATP) stress myocardial strain derived from feature tracking (FT) as a novel method for detecting IHD in a swine model. MATERIALS AND METHODS: CMR cines, myocardial perfusion imaging at rest and during ATP stress, and late gadolinium enhancement were obtained in both control and IHD swine. Normal, remote, ischemic, and infarcted myocardium were analyzed. The diagnostic accuracy of myocardial strain for infarction and ischemia was assessed using coronary angiography and pathology as reference. RESULTS: Eleven IHD swine and five healthy control swine were enrolled in this study. Strain parameters, even at rest, were associated with myocardial ischemia and infarction(all p < 0.05). The area under receiver operating characteristic curve (AUC) values of all strain parameters for detecting infarcted myocardium exceeded 0.900 (all p < 0.05). The AUC values for detecting ischemic myocardium were as follows: 0.906 and 0.847 for stress and rest radial strain, 0.763 and 0.716 for stress and rest circumferential strain, 0.758 and 0.663 for stress and rest longitudinal strain (all p < 0.001). Heat maps demonstrated that all strain parameters showed mild to moderate correlations with the stress myocardial blood flow and myocardial perfusion reserve (all p < 0.05). CONCLUSION: CMR-FT-derived ATP stress myocardial strain shows promise as a noninvasive method for detecting myocardial ischemia and infarction in an IHD swine model, with rest strain parameters offering potential as a needle-free diagnostic option.


Assuntos
Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Suínos , Animais , Trifosfato de Adenosina , Meios de Contraste , Gadolínio , Valor Preditivo dos Testes , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio/patologia , Infarto/patologia , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos
15.
Int J Cardiovasc Imaging ; 40(2): 249-260, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37971706

RESUMO

A large animal model of chronic coronary artery disease (CAD) is crucial for the understanding the underlying pathophysiological processes of chronic CAD and consequences for cardiac structure and function. The goal of this study was to develop a chronic model of CAD in a swine model and to evaluate the changes of myocardial structure, myocardial motility, and myocardial viability during coronary stenosis. A total of 30 swine (including 24 experimental animals and 6 controls) were enrolled. The chronic ischemia model was constructed by using Ameroid constrictor in experimental group. The 24 experimental animals were further divided into 4 groups (6 animals in each group) and were sacrificed at 1, 2, 3 and 4 weeks after operation for pathological examination, respectively. Cardiac magnetic resonance (CMR) was performed preoperatively and weekly postoperatively until sacrificed both in experimental and control group. CMR cine images, rest/adenosine triphosphate (ATP) stress myocardial contrast perfusion and LGE were performed and analyzed. The rest wall thickening (WT) score was calculated from rest cine images. The MPRI (myocardial perfusion reserve index) and MPR (myocardial perfusion reserve) were calculated based on rest and stress perfusion images. Pathology staining including triphenyltetrazolium chloride, HE and picrosirus red staining were performed after swine were sacrificed and collagen volume fraction (CVF) was calculated. The time to formation of ischemic, hibernating, and infarcted myocardium was recorded. In experimental group, from 1w to 4w after surgery, the rest WT score decreased gradually from 35.2 ± 2.0%, 32.0 ± 2.9% to 30.5 ± 3.0% and finally 29.06 ± 1.78%, p < 0.001. Left ventricular ejection fraction was gradually impaired after modeling (58.9 ± 12.6%, 56.3 ± 10.1%, 55.3 ± 9.0%, 53.8 ± 9.9%, respectively). And the MPR and MPRI also decreased stepwise with extent of surgery time (MPRI dropped from 2.1 ± 0.4, 2.0 ± 0.2 to 1.8 ± 0.3 and finally 1.7 ± 0.1, p = 0.004; MPR dropped from 2.3 ± 0.4, 2.1 ± 0.2 to 1.9 ± 0.4 and finally 1.8 ± 0.1, p < 0.001). Stronger associations between MPR, MPRI and CVF were paralleled lower wall thickening scores in fibrosis-affected areas. The ischemic myocardium was first appeared in the first week after surgery (involving ten segments), hibernated myocardium was first appeared in the second week after surgery (involving seventeen segments). LGE was first appeared in eight swine in the third weeks after surgery (16 segments). At 4w after surgery, average 9.6 g scar tissue was found among 6 swine. At the same time, histological analysis established the presence of fibrosis and ongoing apoptosis in the infarcted area. In conclusion, our study provided valuable insights into the pathophysiological processes of chronic CAD and its consequences for cardiac structure and function in a large animal model through combining myocardial motion and stress perfusion.


Assuntos
Cardiomiopatias , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Suínos , Animais , Volume Sistólico , Adenosina , Valor Preditivo dos Testes , Função Ventricular Esquerda , Isquemia Miocárdica/patologia , Isquemia , Espectroscopia de Ressonância Magnética , Fibrose , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Circulação Coronária/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos
16.
Eur Radiol ; 34(2): 1026-1036, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37635167

RESUMO

OBJECTIVES: Left atrial (LA) myopathy, characterized by LA enlargement and mechanical dysfunction, is associated with worse prognosis in hypertrophic cardiomyopathy (HCM) while the impact of sarcomere mutation on LA myopathy remains unclear. We aimed to assess the association between LA myopathy and sarcomere mutation and to explore the incremental utility of LA strain in mutation prediction. METHODS: A total of 105 consecutive HCM patients (mean age 47.8 ± 11.9 years, 71% male) who underwent HCM-related gene screening and cardiac MRI were retrospectively enrolled. LA volume, ejection fraction and strain indices in reservoir, conduit, and booster-pump phases were investigated respectively. RESULTS: Fifty mutation-positive patients showed higher LA maximal volume index (59.4 ± 28.2 vs 43.8 ± 18.1 mL/m2, p = 0.001), lower reservoir (21.3 ± 7.9 vs 26.2 ± 6.6%, p < 0.001), and booster-pump strain (12.1 ± 5.4 vs 17.1 ± 5.0%, p < 0.001) but similar conduit strain (9.2 ± 4.5 vs 9.1 ± 4.5%, p = 0.909) compared with mutation-negative patients. In multivariate logistic regression, LA booster-pump strain was associated with sarcomere mutation (odds ratio = 0.86, 95% confidence interval: 0.77-0.96, p = 0.010) independent of maximal wall thickness, late gadolinium enhancement, and LA volume. Furthermore, LA booster-pump strain showed incremental value for mutation prediction added to Mayo II score (AUC 0.798 vs 0.709, p = 0.024). CONCLUSIONS: In HCM, mutation-positive patients suffered worse LA enlargement and worse reservoir and booster-pump functions. LA booster-pump strain was a strong factor for sarcomere mutation prediction added to Mayo II score. CLINICAL RELEVANCE STATEMENT: The independent association between sarcomere mutation and left atrial mechanical dysfunction provide new insights into the pathogenesis of atrial myopathy and is helpful to understand the adverse prognosis regarding atrial fibrillation and stroke in mutation-positive patients. KEY POINTS: • In patients with hypertrophic cardiomyopathy, left atrial (LA) reservoir and booster-pump function, but not conduit function, were significantly impaired in mutation-positive patients compared with mutation-negative patients. • LA booster-pump strain measured by MRI-derived feature tracking is feasible to predict sarcomere mutation with high incremental value added to Mayo II score.


Assuntos
Cardiomiopatia Hipertrófica , Doenças Musculares , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Sarcômeros/genética , Sarcômeros/patologia , Meios de Contraste , Gadolínio , Átrios do Coração , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/complicações , Imageamento por Ressonância Magnética , Doenças Musculares/complicações , Doenças Musculares/patologia , Mutação
17.
Postgrad Med J ; 100(1182): 228-236, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38142286

RESUMO

PURPOSE: We aimed to develop an artificial intelligence (AI) model based on transrectal ultrasonography (TRUS) images of biopsy needle tract (BNT) tissues for predicting prostate cancer (PCa) and to compare the PCa diagnostic performance of the radiologist model and clinical model. METHODS: A total of 1696 2D prostate TRUS images were involved from 142 patients between July 2021 and May 2022. The ResNet50 network model was utilized to train classification models with different input methods: original image (Whole model), BNT (Needle model), and combined image [Feature Pyramid Networks (FPN) model]. The training set, validation set, and test set were randomly assigned, then randomized 5-fold cross-validation between the training set and validation set was performed. The diagnostic effectiveness of AI models and image combination was accessed by an independent testing set. Then, the optimal AI model and image combination were selected to compare the diagnostic efficacy with that of senior radiologists and the clinical model. RESULTS: In the test set, the area under the curve, specificity, and sensitivity of the FPN model were 0.934, 0.966, and 0.829, respectively; the diagnostic efficacy was improved compared with the Whole and Needle models, with statistically significant differences (P < 0.05), and was better than that of senior radiologists (area under the curve: 0.667). The FPN model detected more PCa compared with senior physicians (82.9% vs. 55.8%), with a 61.3% decrease in the false-positive rate and a 23.2% increase in overall accuracy (0.887 vs. 0.655). CONCLUSION: The proposed FPN model can offer a new method for prostate tissue classification, improve the diagnostic performance, and may be a helpful tool to guide prostate biopsy.


Assuntos
Inteligência Artificial , Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Próstata/diagnóstico por imagem , Próstata/patologia , Biópsia , Ultrassonografia/métodos
18.
J Transl Med ; 21(1): 921, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115075

RESUMO

BACKGROUND: Metabolic dysfunction-associated fatty liver disease (MAFLD) is one of the most prevalent metabolic syndromes worldwide. However, no approved pharmacological treatments are available for MAFLD. Chenpi, one kind of dried peel of citrus fruits, has traditionally been utilized as a medicinal herb for liver diseases. Didymin is a newly identified oral bioactive dietary flavonoid glycoside derived from Chenpi. In this study, we investigated the therapeutic potential of Didymin as an anti-MAFLD drug and elucidated its underlying mechanisms. METHODS: High-fat diet (HFD)-induced MAFLD mice and alpha mouse liver 12 (AML12) cells were utilized to evaluate the effects and mechanisms of Didymin in the treatment of MAFLD. Liver weight, serum biochemical parameters, and liver morphology were examined to demonstrate the therapeutic efficacy of Didymin in MAFLD treatment. RNA-seq analysis was performed to identify potential pathways that could be affected by Didymin. The impact of Didymin on Sirt1 was corroborated through western blot, molecular docking analysis, microscale thermophoresis (MST), and deacetylase activity assay. Then, a Sirt1 inhibitor (EX-527) was utilized to confirm that Didymin alleviates MAFLD via Sirt1. Western blot and additional assays were used to investigate the underlying mechanisms. RESULTS: Our results suggested that Didymin may possess therapeutic potential against MAFLD in vitro and in vivo. By promoting Sirt1 expression as well as directly binding to and activating Sirt1, Didymin triggers downstream pathways that enhance mitochondrial biogenesis and function while reducing apoptosis and enhancing lipophagy. CONCLUSIONS: These suggest that Didymin could be a promising medication for MAFLD treatment. Furthermore, its therapeutic effects are mediated by Sirt1.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Sirtuína 1 , Animais , Camundongos , Sirtuína 1/metabolismo , Biogênese de Organelas , Simulação de Acoplamento Molecular , Flavonoides/farmacologia , Flavonoides/uso terapêutico , Glicosídeos/farmacologia , Hepatopatia Gordurosa não Alcoólica/metabolismo , Fígado/metabolismo
19.
Radiol Cardiothorac Imaging ; 5(5): e220127, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37908550

RESUMO

Purpose: To determine the association of myocardial fibrosis and left ventricular (LV) dyssynchrony measured using cardiac MRI with late gadolinium enhancement (LGE) and feature tracking (FT), respectively, with response to cardiac resynchronization therapy (CRT) for nonischemic dilated cardiomyopathy (DCM). Materials and Methods: This retrospective study included 98 patients (mean age, 59 years ± 10 [SD]; 54 men) who had nonischemic DCM, as assessed with LGE cardiac MRI before CRT. Cardiac MRI FT-derived dyssynchrony was defined as the SD of the time-to-peak strain (TTP-SD) of the LV segments in three directions (longitudinal, radial, and circumferential). CRT response was defined as a 15% increase in LV ejection fraction (LVEF) at echocardiography at 6-month follow-up, and then, long-term cardiovascular events were assessed. The likelihood ratio test was used to evaluate the incremental prognostic value of LGE and dyssynchrony parameters. Results: Seventy-one (72%) patients showed a favorable LVEF response following CRT. LGE presence (odds ratio: 0.14 [95% CI: 0.04, 0.47], P = .002; and hazard ratio: 3.52 [95% CI: 1.37, 9.07], P = .01) and lower circumferential TTP-SD (odds ratio: 1.04 [95% CI: 1.02, 1.07], P = .002; and hazard ratio: 0.98 [95% CI: 0.96, 1.00], P = .03) were independently associated with LVEF nonresponse and long-term outcomes. Combined LGE and circumferential TTP-SD provided the highest discrimination for LVEF nonresponse (area under the receiver operating characteristic curve [AUC]: 0.89 [95% CI: 0.81, 0.94], sensitivity: 84.5% [95% CI: 74.0%, 92.0%], specificity: 85.2% [95% CI: 66.3%, 95.8%]) and long-term outcomes (AUC: 0.84 [95% CI: 0.75, 0.91], sensitivity: 76.9% [95% CI: 56.4%, 91.0%], specificity: 87.0% [95% CI: 76.7%, 93.9%]). Conclusion: Myocardial fibrosis and lower circumferential dyssynchrony assessed with pretherapy cardiac MRI were independently associated with unfavorable LVEF response and long-term events following CRT in patients with nonischemic DCM and may provide incremental value in predicting prognosis.Keywords: MR Imaging, Cardiac, Outcomes Analysis Supplemental material is available for this article. © RSNA, 2023.

20.
Small ; : e2306701, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37948419

RESUMO

Bi2 Te3 -based alloys are the benchmark for commercial thermoelectric (TE) materials, the widespread demand for low-grade waste heat recovery and solid-state refrigeration makes it imperative to enhance the figure-of-merits. In this study, high-performance Bi0.5 Sb1.5 Te3 (BST) is realized by incorporating Cu2 GeSe3 and Se. Concretely, the diffusion of Cu and Ge atoms optimizes the hole concentration and raises the density-of-states effective mass (md * ), compensating for the loss of "donor-like effect" exacerbated by ball milling. The subsequent Se addition further increases md * , enabling a total 28% improvement of room-temperature power factor (S2 σ), reaching 43.6 µW cm-1  K-2 compared to the matrix. Simultaneously, the lattice thermal conductivity is also significantly suppressed by multiscale scattering sources represented by Cu-rich nanoparticles and dislocation arrays. The synergistic effects yield a peak ZT of 1.41 at 350 K and an average ZT of 1.23 (300-500 K) in the Bi0.5 Sb1.5 Te2.94 Se0.06 + 0.11 wt.% Cu2 GeSe3 sample. More importantly, the integrated 17-pair TE module achieves a conversion efficiency of 6.4%, 80% higher than the commercial one at ΔT = 200 K. These results validate that the facile composition optimization of the BST/Cu2 GeSe3 /Se is a promising strategy to improve the application of BST-based TE modules.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...